FLUKE 116 HVAC MULTIMETER

Multimeters

EGP 31,502.40/Each (ex VAT)
EGP 36,227.76/Each (inc VAT)
Stock No. 6161476
Manufacturer Fluke
Part No. FLUKE 116
Origin CHINA
Supplied/Stocked By RS Components Ltd.

Please enter quantity.

Fluke 16 True RMS HVAC Digital Multimeter with Built-In Thermometer

The Fluke 16 Digital Multimeter is designed to function like a standard Multimeter and exclusive HVAC modes, unlike other models in the Fluke 10 series, the Fluke 116 comes with a built-in thermometer, allowing engineers to measure temperature and microamp mode for testing flame sensors to quickly troubleshoot problems for HVAC applications. The Fluke 116 measures resistance, continuity, frequency and capacitance. The Fluke 116 Multimeter are independently tested for safe use in CAT III 600 V Environments.

Why buy the Fluke 116 Digital Multimeter?

• VoltAlertTM Technology for intergrated non-contact voltage detection
• AutoVolt feature for automatic AC/DC voltage selection
• LoZ: Low input impedance to eliminate stray voltage ensures that ghost voltages don’t have an effect on readings
• Large white LED backlight, perfect for when you’re working in darkened areas
• True RMS meanng it will maintain its accuracy when testing on irregular AC connections
• Min/Max/Average to record signal fluctuations
• Current measurement 20A (30 seconds momentary; 10A continuous)
• Resistance , continuity, frequency and capacitance testing capability

Fluke 116 HVAC Digital Multimeter key benefits?

• Compact, Ergonomic design and can be used with one hand
• Built-in thermometer allows Temperature measurement from -40°C to +400°C using the Type K thermocouple input adaptor
• Capacitance up to 10000μF to test motor start and run capacitors
• Microamp current range for flame sensor measurement down to μA
• 4000 count auto ranging Multimeter
• 40MΩ resistance range
• 33 segment analogue bargrapgh on display
• Diode test
• Continuity test
• V-Check™ mode for safety. Automatically switches from ohm/continuity mode to measure ac or dc volts when voltages above 4.5V are present at the input
• Min/Max recording with elapsed time (ideal for recording signal fluctuations)
• Continuity capture symbolically displays open and short circuits as brief as 250μs
• Meets IEC1010-1 (safety standard) CAT III 600V
• Replacement type K thermocouple available separately accepts other type K thermocouple sensors with subminiature connectors (see accessories)

What are the typical Applications for the Fluke 116 Digital Multimeter?

The Fluke 116 model is built for engineers who work in the HVAC environment (heating, ventilation and air conditioning)

Additional Specification

• DC Voltage Accuracy: 0.5% +2d
• AC Voltage Accuracy: 2.0% +3d
• DC Current Accuracy 1.0% +2d
• AC Current Accuracy 1.5% +3d
• Resistance Accuracy: 1.5% +2d
• Diode Test Range: 2.000V
• Diode Test Resolution: 0.001V
• Diode Test Accuracy: 0.9% +2d
• Capacitance Accuracy: 1.9% +2d
• Temperature Resolution 0.1C
• Temperature Accuracy 1% +10d
• Display Count 6000
• Display Update 4/sec
• Bar Graph Segments 33
• Bar Graph Update 32/sec
• Please note accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %."

Does the Fluke 116 come with a warranty?

The Fluke 116 comes with a 3 year warranty giving engineers the peace of mind Standards From Fluke, the 116 is designed for heating, ventilation and air conditioning (HVAC) engineers. The model includes temperature measurement and microamp current ranges to quickly troubleshoot HVAC problems.
Specifications
Dimensions 46 x 84 x 167mm
Width 84mm
Maximum Operating Temperature +50°C
Battery Life 400 h
Absolute Maximum Temperature Measurement +400°C
Height 167mm
DC Current Measurement Resolution 0.1µA
Length 46mm
Multimeter Type Handheld
Resistance Measurement Resolution 100mΩ
Weight 550g
Battery Type 9V
Best Capacitance Measurement Accuracy ±1.9% + 2 Digits
AC Voltage Measurement Resolution 0.1mV ac
Absolute Maximum Resistance Measurement 40MΩ
Model Number p 116
Best DC Voltage Accuracy ±0.5% + 2 Digits
DC Voltage Measurement Resolution 0.1mV dc
Safety Category Voltage 600V
Minimum Operating Temperature -10°C
Safety Category Level CAT III
True RMS Yes
AC Current Measurement Resolution 0.1µA
Best Resistance Measurement Accuracy ±1.5% + 2 Digits
Absolute Maximum DC Current Measurement 600µA dc
Absolute Maximum AC Current Measurement 600µA ac
Best AC Voltage Accuracy ±1% + 3 Digits
Display Type LCD
Absolute Maximum DC Voltage Measurement 600V dc
Temperature Measurement Resolution 0.1°C
Capacitance Measurement Resolution 1nF
Absolute Maximum Capacitance Measurement 9.999F
Absolute Maximum AC Voltage Measurement 600V ac
Maximum Frequency 1kHz
Best AC Current Accuracy ±1.5% + 3 Digits
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Resistance, Temperature
Best Temperature Measurement Accuracy ±1% + 1 °C
Best DC Current Accuracy ±1% + 2 Digits